Safety Laser Scanner
SZ series
Main Unit, Communication Type SZ-16D
*Please note that accessories depicted in the image are for illustrative purposes only and may not be included with the product.
Specifications
Model  | SZ-16D  | |||
Type  | Communication type  | |||
Detection capability  | Minimum detectable object size  | Diameter 30 mm, 40 mm, 50 mm, 70 mm, 150 mm (depends on the setting)  | ||
Detectable angle  | 270° (-45° to 225°)  | |||
Response time (ON to OFF)  | General scan cycle (Scan cycle A)  | 60 ms (2 scanning) to 480 ms (16 scanning)  | ||
Specific scan cycle (Scan cycle B)  | 66 ms (2 scanning) to 528 ms (16 scanning)  | |||
Response time (OFF to ON)  | General scan cycle (Scan cycle A)  | Response time of ON to OFF + 125 ms  | ||
Specific scan cycle (Scan cycle B)  | ||||
Max. protection zone  | Minimum detectable object size: 70 mm /150 mm  | 4.2 m (-5° to 185°), 2.8 m (-45° to -5°, 185° to 225°)  | ||
Minimum detectable object size: 50 mm  | 3.0 m (-5° to 185°), 2.0 m (-45° to -5°, 185° to 225°)  | |||
Minimum detectable object size: 40 mm  | 2.4 m (-5° to 185°), 1.6 m (-45° to -5°, 185° to 225°)  | |||
Minimum detectable object size: 30 mm  | 1.8 m (-5° to 185°), 1.2 m (-45° to -5°, 185° to 225°)  | |||
Max. warning zone (non safety related)  | Minimum detectable object size: 70 mm /150 mm  | 10.0 m (-5° to 185°), 7.0 m (-45° to -5°, 185° to 225°)*1  | ||
Minimum detectable object size: 50 mm  | 7.5 m (-5° to 185°), 5.0 m (-45° to -5°, 185° to 225°)*1  | |||
Minimum detectable object size: 40 mm  | 6.0 m (-5° to 185°), 4.0 m (-45° to -5°, 185° to 225°)*1  | |||
Minimum detectable object size: 30 mm  | 4.5 m (-5° to 185°), 3.0 m (-45° to -5°, 185° to 225°)*1  | |||
Additional safety distance  | 100 mm*2  | |||
Light source  | Type, wavelength  | Infrared laser diode, 905 nm  | ||
Laser class  | Class 1 IEC / EN 60825-1: 2007  | |||
OSSD output  | Output  | PNP or NPN (Selectable according to the connector cable)  | ||
Max. load current  | 500 mA*3  | |||
Residual voltage (during ON)  | Max. 2.5 V (with a cable length of 5 m)  | |||
OFF-state voltage  | Max. 2.0 V (with a cable length of 5 m)  | |||
Leakage current  | Max. 1 mA*4  | |||
Max. capacitive load  | 2.2 µF (with a load resistance of 100 Ω)  | |||
Load wiring resistance  | Max. 2.5 Ω*5  | |||
Input (safety-related)  | Input resistance  | 4.4 kΩ (for Input 1 and 3 to 10)  | ||
Nonsafety-relatedoutput (AUX output)  | Output  | PNP/NPN totem pole output  | ||
Max. load current  | 50 mA  | |||
Residual voltage (during ON)  | Max. 2.5 V (with a cable length of 5 m)  | |||
Cable length  | 30 m or less*6  | |||
Approved standards  | EMC  | EMS  | IEC61496-1, EN61496-1, UL 61496-1  | |
EMI  | EN55011 Class A, FCC Part15B Class A  | |||
Safety  | IEC61496-1, EN61496-1, UL 61496-1 (Type 3 ESPE)  | |||
Rating  | Power voltage  | When using a converter power supply: 24 VDC ±10 %, Ripple (P-P) 10 % or less  | ||
Power consumption  | Max. 10.5 W (without load)  | |||
Environmental resistance  | Enclosure rating  | IP65 (IEC60529)*7  | ||
Ambient light  | Incandescent lamp: 1,500 lux or less*8  | |||
Operating ambient temperature  | -10 to +50 °C (No freezing)  | |||
Operating relative humidity  | 35 to 85 % RH (No condensation)  | |||
Storage temperature  | -25 to +60 °C (No freezing)  | |||
Storage relative humidity  | 35 to 95 % RH  | |||
Vibration resistance  | 10 to 55 Hz, Double amplitude 0.7 mm, 20 sweeps in each of the X, Y, and Z directions  | |||
Shock resistance  | 100 m/s2 (Approx. 10 G), 16 ms pulse, 1,000 times in each of the X, Y, and Z directions  | |||
Material  | Main unit case  | Aluminum die casting, SPHC (Bottom)  | ||
Window  | Polycarbonate  | |||
Weight  | Approx. 1.6 kg  | |||
*1 20% or more reflectance is necessary for the minimum detectable object in the warning zone.  | ||||