Specs Colour LCD Monitor CA-M series

Model

CA-MP81

Image

Display panel

Display colour

a-Si, TFT active matrix method

262144

No. of dots

800 (W) x 600 (H) dots

Active display area

170.4 mm (W) x 127.8 mm (H)

Structure

Panel-mount type, Only the front face is dust-proof and splash-proof equivalent to IP65f.

Backlight

Operation life

Approx. 50,000 hours (average)
(When installed in an upright position under 25 °C)

Input/Output

Input signal

Analog RGB signal (0.7 Vp-p,
75 Ω), Horizontal/vertical
synchronization signal

Input signal mode

800 (W) x 600 (H),
Vertical frequency: 60 Hz

Connector

High-density D-sub 15-pin female (3-way, inch screw)

Rating

Power voltage

24 VDC ±10 %

Current consumption

1 A max.

Environmental resistance

Ambient temperature

0 to +40 °C

Relative humidity

35 to 85 % RH (No condensation)

Weight

Approx. 1,200 g

Back to top

Model

CA-S20D *1

Image

No. of adjustable axes

4

Angular
travel range

Front/back adjustment

0 to 100°

Horizontal adjustment

±5°

Left/right adjustment

Horizontal travel range

±20 mm

Scale display

Angle

Display resolution 1° (0.1° when using vernier scale)

Distance

Display resolution 1 mm (0.1 mm when using vernier scale)

Adjustment
screw pitch

Front/back rotation

- (manual)

Horizontal rotation

2.3°/turn

Left/right rotation

Horizontal travel

10 mm/turn

Withstand load

3 kg

Lock function

Lockscrews, torqued to 50 cN m

Environmental resistance

Ambient temperature

0 to +50 °C

Relative humidity

85% RH or less (no condensation)

Weight

1.3 kg

*1 Compatible camera models:
CA-HL02MX/04MX/08MX, CA-HF6400C/M, CA-HF2100C/M, CA-H048CX/MX, CA-H200CX/MX, CA-H500CX/MX

Back to top

Model

CA-U4

Image

Type

24 VDC Power supply

Input conditions

Rated input voltage

85 to 264 VAC , 47 to 63Hz , 110 to 370 VDC*1

Efficiency

82% (100 VAC)/85% (200 VAC)typ. (with 100% load)

Rated input current

2.2 A or less (100 VAC)/1.1 A or less (200 VAC)

Output conditions

Rated output voltage

24 VDC

Rated output current

6.5A

Protection

Overvoltage protection

Constant current voltage limiting. Automatic reset 7.9 A min.

Activates at 26.4 V or more. Voltage interruption method,
recovers when input is applied again.*2

Applicable standards

Safety standards

UL : UL508、UL60950-1
C-UL : CSA C22.2 No.14-M95, CSA C22.2 No.60950-1-03
EN : EN62368-1、EN50178
IEC : IEC62368-1

EMC standard

FCC Part15B Class A, EN55011 Class A, EN61000-6-2

Limits for harmonic current emissions

EN61000-3-2

Environmental resistance

Ambient temperature

-10 to +55 °C (No freezing)

Storage temperature

-20 to +70 °C (No freezing)

Relative humidity

85% RH or less (no condensation)

Weight

Approx 700 g

*1 The rated input voltage and rated frequency when applying for safety standards are 100 to 240 VAC, 50/60 Hz.
*2 To recover, turn off the input power supply, leave it off for 1 minute or more, and then turn it on again.

Back to top