Specs Digital RGB Sensors CZ-V20 series

Sensor head

Model

CZ-H32

CZ-H35S

CZ-H37S

CZ-H52

CZ-H72

Image

Type

Adjustable spot

Lustre cancel

Lustre-cancel, small beam spot

Fluorescence detection UV

Lustre detection (Adjustable beam spot)

Detecting area

50 to 95 mm
(Reco mmended: 70 mm)

28 to 52 mm
(Reco mmended: 40 mm)

11 to 20 mm
(Reco mmended: 15 mm)

25 to 55 mm
(Reco mmended: 35 mm)

15 mm (Centre)*3

Smallest spot diameter

Small: 3 mm dia.
Medium: 4.5 mm dia.
Large: 5.5 mm dia .
at respective reference distance*1

4.5 mm dia. at reference distance of 40 mm

1 mm dia. at reference distance of 16 mm

Approx. 10 mm dia. at reference distance of 25 mm

Small: approx. 3 mm dia., Large: approx. 5 mm dia.
at reference distance of 15 mm

Light source

Red LED (665 nm)/Green LED (520 nm)/Blue LED (465 nm)

UV (ultraviolet) LED (375 nm) *2

Red LED (665 nm)

Minimum bend radius of fi bre

25 mm

15 mm

―

25 mm

Receivable wavelength (Receiver)

425 to 550 nm

Environmental resistance

Enclosure rating

IP40

Ambient light

Incandescent lamp: 10,000 lux max., Sunlight: 20,000 lux max.

Ambient temperature

-10 to +55 °C (No freezing)

Vibration resistance

10 to 55 Hz, Double amplitude 1.5 mm, 2 hours in each of the X, Y, and Z axis

Material

Housing:Fibreglass reinforced plastic , Lens cover:Polyarylate

Housing:Triacetate, Polyarylate (Metal section: TYPE 304 stainless steel) , Lens cover:Fibreglass reinforced plastic

Housing:Fibreglass reinforced plastic , Lens cover:Glass

Weight

Approx. 40 g

Approx. 45 g

Approx. 40 g

Approx. 50 g

*1 Reference distance: 65 mm for Small, 60 mm for Medium, and 50 mm for Large
*2 The CZ-H52 emits ultraviolet light from the transmitter. Do not directly look at the light
source while in operation.
*3 Small beam spot: 15 ±3 mm , Large beam spot: 15 ±5 mm

Back to top

Amplifier

Model

CZ-V21A*1

CZ-V21AP*1

CZ-V22A*1

CZ-V22AP*1

Image

Output

NPN output

PNP output

NPN output

PNP output

Main unit/Expansion unit

Main unit

Expansion unit

Response time

200 µs (HIGH SPEED) /1 ms (FINE) /4 ms (TURBO) /8 ms (SUPER)

Control output

NPN open-collector x 4 channels, 40 VDC max., Up to 100 mA for one output, Up to 200 mA in total of 4 outputs, Residual voltage: 1.0 V max.*2

PNP open-collector x 4 channels, 30 VDC max., Up to 100 mA for one output, Up to 200 mA in total of 4 outputs, Residual voltage: 1.0 V max.*2

NPN open-collector x 4 channels, 40 VDC max., Up to 100 mA for one output, Up to 200 mA in total of 4 outputs, Residual voltage: 1.0 V max.*2

PNP open-collector x 4 channels, 30 VDC max., Up to 100 mA for one output, Up to 200 mA in total of 4 outputs, Residual voltage: 1.0 V max.*2

Protection circuit

Reverse-polarity protection, overcurrent protection, surge absorber

External tuning input, external bank switch input (C/C + I-mode), external shift input (super I-mode)

Input time: 20 ms min.

Timer function

Timer OFF/OFF-delay/ON-delay/One-shot, Timer time: 1 to 1000 ms adjustable (for each bank respectively)

Unit expansion

Up to 3 units (4 units total including the main unit)

Number of interference prevention units

0 for HIGH SPEED; 2 for FINE/TURBO/SUPER

Rating

Power voltage

24 VDC, Ripple (P-P) 10 % or less

Power consumption

Normal mode: 1.5 W (62.5 mA or less), Eco-mode: 1 W (42.0 mA or less)

Environmental resistance

Ambient temperature

-10 to +55 °C (No freezing)*3

Vibration resistance

10 to 55 Hz, Double amplitude 1.5 mm, 2 hours in each of the X, Y, and Z axis

Material

Housing, cover: Polycarbonate

Accessories

Mounting Fittings

End Unit × 2

Weight

Approx. 110 g

Approx. 100 g

*1 The expansion unit of the FS-V20 Series cannot be connected to the main unit of the CZ-V20 Series. To connect the FS and CZ Series units, connect the expansion unit of the CZ-V20 Series to
the main unit of the FS-V20 Series.
To connect two or more expansion units, connect the CZ-V20 Series units on the right of the FS-V20 Series units.
*2 20 mA max. when several units are connected.
*3 When several units are connected, the acceptable ambient temperature varies depending on the conditions given below. To connect several units, be sure to mount them to a DIN rail and to limit the output
current to a maximum of 20 mA.
When 1 or 2 units are connected: -10 to +50 °C
When 3 units are connected: -10 to +45 °C

Back to top