Model

DL-PD1

Sensor
connection
specifications

Connectable
sensors

Sensor amplifiers with D-bus support*1

Number of
connectable
sensor units

15 units max.*2

PROFIBUS
DP
specifications

Device type

DP-V1 Slave (D-sub 9 pin, Number of the ports: 1)

Communication speed

9.6 kbit/s to 12 Mbit/s

Cable length

9.6 / 19.2 / 45.45 / 93.75 kbit/s : 1200 m
187.5 kbit/s : 1000 m
500 kbit/s : 400 m
1.5 Mbit/s : 200 m
3 / 6 / 12 Mbit/s : 100 m

Power voltage

20 to 30 VDC, including ripple (p-p) 10%
(This voltage is supplied from the connected sensor amplifier.)

Power consumption

1600 mW or less (65 mA max. at 24 V)

Environmental resistance

Ambient temperature

-20 to +55 °C (No freezing)

Relative humidity

35 to 85 % RH (No condensation)

Vibration resistance

10 to 55 Hz, Double amplitude 1.5 mm, 2 hours in each of the X, Y, and Z directions

Shock resistance

500 m/s2, 3 times in each of the X, Y, and Z directions

Material

Main unit case and dust cover: Polycarbonate PROFIBUS connector: Steel – Nickel plating

Weight

Approx. 65 g

*1 "D-bus" is the name of KEYENCE's wiring-saving system for sensor amplifiers.
*2 Varies with the sensor amplifiers connected.