          SPECIFICATIONS

          Select Language

          Model

          FU-96T*1

          Type

          Thrubeam

          Fibre unit length

          2 m free-cut

          Fibre unit diameter

          ø2.2

          Minimum bend radius

          R25 mm*2

          Minimum detectable object

          Opaque material with a diameter of 0.2 mm*3

          Tightening torque

          0.2 N m or less

          Environmental resistance

          Enclosure rating

          IP67*4

          Ambient temperature

          0 to +60 °C (No condensation and no freezing)*5

          Relative humidity

          35 to 85 % RH (No condensation and No freezing)*6

          Material

          Main unit case : PFA, fibre sheath : PFA*4

          Accessories

          Fibre cutter

          Weight

          Approx. 35 g

          *1 For details on the detecting distance, see the fibre amplifier catalogue.
          *2 The section 25 mm in length from the screw cap tip of the main unit case cannot be bent.
          *3 The minimum detectable object is the value when the detecting distance and sensitivity have been set to their optimal state.
          *4 Using this product in high-temperature liquids or steam may lead to penetration of the fluorocarbon polymers, which may cause fluctuations in the received light intensity and damage to the internal components.
          *5 Use this product under the condition that if the ambient temperature exceeds 60 °C, the absolute humidity is 60 °C 85%RH or less.
          *6 Use this product under the condition that if the ambient temperature exceeds 60 °C, the absolute humidity is 60 °C 85 % RH or less.

          • For Beginners Sensor Basics Understanding fundamental - Introduction Guide to Sensors
          • General Catalogue Request
          • Trade Shows and Exhibitions
          • eNews Subscribe

          Back to top

          KEYENCE CANADA INC. 6775 Financial Drive, Suite 202, Mississauga, ON L5N 0A4, Canada
          Phone:1-888-KEYENCE [1-888-539-3623]
          E-mail: keyencecanada@keyence.com
          Career Opportunities: KEYENCE Career Site

          Sensors