Safety Light Curtain
SL-V series
Main Unit, Robust Type, 71 Optical Axes SL-V71FM
 
*Please note that accessories depicted in the image are for illustrative purposes only and may not be included with the product.
Specifications
| Model | SL-V71FM | |||
| Detection capability | ø14 mm | |||
| Beam axis spacing/Lens diameter | 10 mm/ø4 mm | |||
| Effective aperture angle | Max. ±2.5 ° (When operating distance is 3 m or more) | |||
| Working distance | 0.1 to 7 m | |||
| Response time (ms) | ON→OFF | 15.7*1 | ||
| OFF→ON | 55.7*1 | |||
| Light source | Infrared LED (850 nm) | |||
| Operation mode | Turns on when no interruptions are present in the detection zone (excluding when the muting function is used) | |||
| OSSD output | Output | 2 outputs each for PNP and NPN. Can be changed by using the connector cable. | ||
| Max. l oad current | 500 mA*2 | |||
| Residual vol tage (during ON) | Max. 2.5 V (with a cable length of 7 m) | |||
| Leakage current | Max. 100 µA*3 | |||
| Max. capacitive load | 2.2 µF (with a load resistance of 100 Ω) | |||
| Load wiring resistance | Max. 2.5 Ω*4 | |||
| Non safety-rel atedoutput | AUX | Output with automatic PNP/NPN switching function, 50 mA max. | ||
| Interlock-reset-ready output | ||||
| Alarm output | ||||
| Clear/blocked output | ||||
| State information output 1, 2 | ||||
| Muting lamp output | Incandescent lamp (24 VDC, 1 to 7 W) or LED lamp (load current: 10 to 300 mA)*5 can be connected | |||
| Input | EDM input | Short-circuit current 10 mA | ||
| Wait input | Short-circuit current 2.5 mA | |||
| Reset input | ||||
| Muting input 1, 2 | ||||
| Override input | ||||
| Protection circuit | Reverse current protection, short-circuit protection for each output, surge protection for each output | |||
| Approved standards | EMC | EMS | IEC61496-1, EN61496-1, UL61496-1 | |
| EMI | EN55011 Class A, FCC Part15B Class A | |||
| Safety | IEC61496-1, EN61496-1, UL61496-1 (Type 4 ESPE) | |||
| Rating | Power voltage | 24 VDC +10 %, -20 %, Ripple (P-P) 10 % or less | ||
| Current consumption (mA) | When the Centre indicator is ON | Transmitter | 136*6 | |
| Receiver | 92*6 | |||
| When the Centre indicator is OFF | Transmitter | 129*6 | ||
| Receiver | 83*6 | |||
| Environmental resistance | Enclosure rating | IP65/67 (IEC60529) | ||
| Overvoltage category | II | |||
| Ambient light | Incandescent lamp: 5,000 lux max., Sunlight: 20,000 lux max. | |||
| Operating ambient temperature | -10 to +55 °C (No freezing) | |||
| Operating relative humidity | 15 to 85 % RH (No condensation) | |||
| Storage temperature | -25 to +60 °C (No freezing) | |||
| Storage relative humidity | 15 to 95 % RH | |||
| Vibration resistance | 10 to 55 Hz, Double amplitude 0.7 mm, 20 sweeps in each of the X, Y, and Z directions | |||
| Shock resistance | 100 m/s2 (Approx. 10 G), 16 ms pulse, 1,000 times in each of the X, Y, and Z directions | |||
| Material | Main unit case | Aluminium | ||
| Upper case/lower case | Zinc die-cast | |||
| Front cover | Polycarbonate, SUS304 | |||
| Weight | Transmitter | 1,610 g | ||
| Receiver | 1,630 g | |||
| *1 When connecting the SL-V units in series, the response time (ON to OFF) is the sum of theresponse times of al l the individual SL-V units, but the response time (OFF to ON) is the sameas that of a singl e SL-V unit. | ||||