Two-colour Digital Display Pressure Sensor
AP-30 series
Specs Two-colour Digital Display Pressure Sensor AP-30 series
Main unit: PNP
| 
         Model  | 
        
         AP-31P  | 
    |||
| 
         Image  | 
        
         
  | 
    |||
| 
         Type  | 
        
         Negative pressure, PNP  | 
    |||
| 
         Rated pressure  | 
        
         0 to -1.013 bar (0 to -101.3 kPa)  | 
    |||
| 
         Fluid type  | 
        
         Air or non-corrosive gases  | 
    |||
| 
         Type of pressure  | 
        
         Gauge pressure  | 
    |||
| 
         Display  | 
        
         3 1/2-digit, 2-colour, 7-segment LED (Character height: 11 mm)  | 
    |||
| 
         Display resolution  | 
        
         0.001 bar, 0.1 inchHg, 0.1 kPa, 1 mmHg  | 
    |||
| 
         Detectable pressure range  | 
        
         -15 to +110 % of F.S.  | 
    |||
| 
         Display temperature characteristic  | 
        
         ±1 % max. (of F.S.) of detecting pressure at 25 °C (0 to 50 °C)  | 
    |||
| 
         Temperature fluctuation for analogue output  | 
        
         ±2 % max. (of F.S.) of detecting pressure at 25 °C (0 to 50 °C)  | 
    |||
| 
         Response time (Chattering prevention function)  | 
        
         2.5/5/100/500 ms (selectable)  | 
    |||
| 
         I/O  | 
        
         Analogue output  | 
        
         1 to 5 V (Load impedance: 47 kΩ min.)  | 
    ||
| 
         Control output  | 
        
         2 PNP open-collector: 100 mA max. (30 V max.), Residual voltage: 1 V max. 2-output (N.O./N.C.selectable)  | 
    |||
| 
         Rating  | 
        
         Power voltage  | 
        
         12 to 24 VDC ±10 %, Ripple (P-P) 10 % or less  | 
    ||
| 
         Current consumption  | 
        
         50 mA (at 24 V) or less, 90 mA (at 12 V) or less  | 
    |||
| 
         Environmental resistance  | 
        
         Pressure resistance  | 
        
         5.0 bar (500 kPa)  | 
    ||
| 
         Ambient temperature  | 
        
         0 to +50 °C (No freezing)  | 
    |||
| 
         Relative humidity  | 
        
         35 to 85 % RH (No condensation)  | 
    |||
| 
         Vibration resistance  | 
        
         10 to 55 Hz, Double amplitude 1.5 mm, 2 hours in each of the X, Y, and Z directions  | 
    |||
| 
         Material  | 
        
         Front housing: Polyamide, Front panel sheet: PET, Rear housing: Polysulfone,  | 
    |||
| 
         Weight  | 
        
         Approx. 120 g (including 2 m cable)  | 
    |||