Recent Searches
    Series ( results)
      Models ( results)
        Keywords

          Wide-Area 3D Measurement SystemVR series

          VR-3000K

          Wide-Area 3D Measurement System Controller

          SPECIFICATIONS

          Select Language

          Model

          VR-3000K

          Type

          Controller

          Head

          VR-3100,VR-3050

          Field-of-view

          Wide-field mode

          Magnification on a
          15" monitor 12x

          Horizontal

          24 mm

          Vertical

          18 mm

          Magnification on a
          15" monitor 25x

          Horizontal

          24 mm

          Vertical

          Magnification on a
          15" monitor 38x

          Horizontal

          Vertical

          Magnification on a
          15" monitor 50x

          Horizontal

          Vertical

          High magnification mode

          Magnification on a
          15" monitor 40x

          Horizontal

          Vertical

          Magnification on a
          15" monitor 80x

          Horizontal

          Vertical

          Magnification on a
          15" monitor 120x

          Horizontal

          Vertical

          Magnification on a
          15" monitor 160x

          Horizontal

          Vertical

          Zoom

          1 to 4x

          Measurable height

          Wide-field mode:10 mm (±5 mm) High magnification mode:1 mm(±0.5 mm)*1

          Repeatability(σ)

          Height measurement

          0.5 µm*2

          Width measurement

          Wide-field mode: 1 µm, High magnification mode: 0.5 µm*2

          Measurement
          accuracy

          Height measurement

          ±3 µm*2

          Width measurement

          Wide-field mode: ±5 µm, High magnification mode: ±2 µm*2

          Stitching function

          Full automatic (XY stage automatic control + auto focus) measurement*3
          Auto adjustment, Auto template analysis*3
          Manual (XY, Z)*3

          Stage

          XY stroke

          184 × 88 mm (motorized)
          70 mm *4 (200 mm *5) (manual)

          Z stroke

          90 mm(electric)

          Rotation

          ±90°

          Tilt

          Over ±30°

          Working distance

          75 mm

          Image receiving element

          4 megapixel monochrome CMOS

          Transmitter lens

          Double telecentric lens x2

          Receiver lens

          Double telecentric lens

          Light sources

          Observation light source

          LED ring light (red, green, blue)(VR-3100),LED ring light (white)(VR-3050)

          Measurement light source

          White LED

          Image size

          1024 x 768 pix, 2048 x 1536 pix

          Data processing

          Dedicated PC specified by KEYENCE (OS: Windows 7)*6

          Rating

          Power voltage

          100 to 240 VAC, 50/60 Hz

          Power consumption

          150 VA

          Environmental resistance

          Ambient temperature

          +15 to +30 °C

          Relative humidity

          35 to 80 % RH (No condensation)

          Weight

          3.8 kg

          *1 Low range ±5 mm 0.20" and high range ±0.5 mm ±0.02" around the focal point position.
          *2 Value obtained using KEYENCE's specified standard gauge with measurement in KEYENCE's specified measurement mode (ambient temperature: 23±1°C).
          *3 The stitching module (VR-H2J) is required.
          *4 The VR-3050 requires the XYθ stage (OP-87715).
          *5 When the OP-87717 manual slider for stitching used.
          *6 Windows 7 Professional and Ultimate.

          Microscope Library