Rugged Industrial Handheld Code Reader

HR-X series

Catalogues View Catalogue

Rugged Industrial Handheld Code Reader DPM model HR-X500

HR-X500 - Rugged Industrial Handheld Code Reader DPM model

*Please note that accessories depicted in the image are for illustrative purposes only and may not be included with the product.

Software

  • CE Marking
  • UL Listing(c/us)

Specifications

Model

HR-X500

Type

DPM model

Wireless/wired

Wired

Receiver

Number of pixels

1920×1200 × 2 cameras
2.3 megapixels × 2 cameras

Sensor

CMOS image sensor

Light emitter

Light source

White LED

LED risk group

Risk group 2 (IEC 62471)

Aimer light source

Laser (red), Wavelength: 650 nm; LED (green)

Laser class

Class 1 (IEC 60825-1)

Distance sensor

Time-of-flight (TOF) sensor

Reading specifications

Supported symbols

2D codes

QR, Micro QR, DataMatrix (ECC200), DMRE, GS1 DataMatrix, PDF417, Micro PDF417, GS1 Composite (CC-A, CC-B, CC-C), DotCode, Maxi Code, Aztec Code

Barcodes

CODE39, ITF, 2of5 (Industrial 2of5), COOP 2of5, NW-7 (Codabar), CODE128, GS1-128, GS1 DataBar, CODE93, JAN/EAN/UPC, Trioptic CODE39, CODE39 Full ASCII, Pharmacode, Postal (Japan Postal, IMB)

Minimum resolution

2D codes

0.040 mm

Barcodes

Reading distance (reference value)

DataMatrix (Module size: 0.25 mm)

10 to 150 mm

DataMatrix (Module size: 0.50 mm)

10 to 250 mm

CODE39 (NB: 0.25 mm)

10 to 300 mm

CODE39 (NB: 0.50 mm)

10 to 500 mm

Status display output/buttons

OLED + Buzzer + Vibration + Function button

Communication

USB

Standard

USB 2.0 Full Speed

Interface

USB-COM, USB keyboard, RNDIS

Supported OS

Windows 11 Pro, Windows 10 Pro 32/64bit

Bluetooth®

Standard

Profile

Supported OS

Windows 11 Pro, Windows 10 Pro 32/64bit

Wireless LAN

Continuous usage time (reference value)

Charging time

Charging method

Dimensions

231.4 × 102.4 × 74.2 mm

Rating

Power supply voltage

USB power supply

AC adapter

12 V ±10%

Ratings

Current consumption

Max.

1500 mA

During standby

110 mA

Environmental resistance

Enclosure rating

IP65/IP67 (IEC 60529)

Ambient temperature

0 to +45°C

Storage temperature

-20 to +60°C

Charging temperature

0 to +40°C

Relative humidity

Max. 95% RH (no condensation)

Storage relative humidity

Oil resistance

IP67G/ISO 16750-1

Chemical resistance

Supports sterilisation with alcohol

Static electricity resistance

Airborne: ±25 kV; Contact: ±10 kV; Indirect: ±10 kV*1

Electrostatic charge prevention

Drop resistance

Concrete, 2.5 m*2

Repeated drops

30 cm, 20,000 times*2

Material

PC + TPU

Weight

Approx. 440 g
(excluding cables)

*1 Verify that no damage is caused.
*2 These are test values and are not guaranteed.