Recent Searches
    Series ( results)
      Models ( results)
        Keywords

          Vision Sensor

          IV series

          Select Language

          Sensor Head

          Model

          IV-HG500CA

          IV-HG500MA

          IV-HG150MA

          IV-HG300CA

          IV-HG600MA

          Type

          Standard sensor model

          Narrow field of view sensor model

          Wide field of view sensor model

          Installed distance

          20 to 500 mm

          40 to 150 mm

          40 to 300 mm

          40 to 600 mm

          View

          Installed distance 20 mm: 10 (H) x 7.5 (V) mm to
          Installed distance 500 mm: 200 (H) x 150 (V) mm

          Installed distance 40 mm: 8 (H) x 6 (V) mm to
          Installed distance 150 mm: 32 (H) x 24 (V) mm*4

          Installed distance 40 mm: 42 (H) x 31 (V) mm to
          installed distance 300 mm: 275 (H) x 206 (V) mm

          Installed distance 40 mm: 42 (H) x 31 (V) mm to
          installed distance 600 mm: 550 (H) x 412 (V) mm

          Image sensor

          Type

          1/3 inch colour CMOS

          1/3 inch monochrome CMOS

          1/3 inch colour CMOS

          1/3 inch monochrome CMOS

          Pixel

          752 (H) x 480 (V)

          Focus adjustment

          Auto*1

          Exposure time

          1/10 to 1/50,000

          1/20 to 1/50,000

          1/25 to 1/50,000

          1/50 to 1/50,000

          Lights

          Illumination

          White LED

          Infrared LED

          Lighting method

          Pulse lighting/DC lighting is switchable

          Pulse lighting

          Indicators

          2 (the same display details for both indicators)

          Environmental resistance

          Enclosure rating

          IP67*2

          Ambient temperature

          0 to +50 °C (No freezing)

          Relative humidity

          35 to 85 % RH (No condensation)

          Vibration resistance

          10 to 55 Hz, Double amplitude 1.5 mm, 2 hours in each of the X, Y, and Z directions*3

          Shock resistance

          500 m/s2, 3 times in each of 6 directions*3

          Material

          Main unit case: Zinc die-casting, Front cover: Acrylic (hard coat), Operation indicator cover: TPU

          Weight

          Approx. 75 g

          *1 The focusing position can be automatically adjusted at the time of installation. Deactivated during the operation. Focusing position can be registered by programme.
          *2 Except when polarised filter attachment (OP-87899/OP-87900/OP-87901/OP-87902) is mounted
          *3 Except when IV-HG dome attachment (IV-GD05/IV-GD10) is mounted
          *4 Installed distance 18 mm: 4 (H) x 3 (V) mm to installed distance 27 mm: 7 (H) x 5.2 (V) mm when the magnifying lens attachment (OP-87902) is used

          Sensor Amplifier

          Model

          IV-HG10

          IV-HG15

          Type

          Main unit

          Expansion unit

          Tools

          Type

          Shape Detection, Area*1, Colour Area*2, Edge Pixels, Width/Height, Diameter, Edge Presence, Pitch, Position Adjustment, High Speed Position Adjustment (1-Axis/2-Axis Adjustment), OCR*3

          Number

          Detection tools: 16 tools, position adjustment tool: 1 tool*4

          Switch settings (programs)

          32 programmes

          Image history

          Numbers

          When using a colour type head: 100 images*5, when using a monochrome type head: 300 images*6*7

          Condition

          NG only/All is selectable*7

          Analysis information

          OFF/Statistics/Histograms/Matching rate list is switchable
          Statistics: Processing time (latest value, MAX, MIN, AVE), number of OKs, number of NGs, trigger numbers, trigger errors, judgement results list by tools
          Histograms: Histogram, matching degree (latest value, MAX, MIN, AVE), numbers of OKs, numbers of NGs
          Matching rate list: Judgment results list by tools, matching rate list by tools, judgment bar list by tools*8

          Other functions

          HDR, HighGain, Colour filters*2, Digital zoom (2x, 4x)*9, Brightness correction, Tilt correction, White balance*2, Mask function, Colour histogram, Test run, ToolAutoTune, Input monitor, Output test, Security settings, Simulator, Mutual interference prevention, Direct connection (2 units or more), Sensor date/time information addition, Scaling function, Failing sensor list, Failure hold

          Indicators

          PWR/ERR, OUT, TRIG, STATUS, LINK/ACT

          Input

          Type

          Non-voltage input/voltage input is switchable
          For non-voltage input: ON voltage 2 V or lower, OFF current 0.1 mA or lower, ON current 2 mA (short circuit)
          For voltage input: Maximum input rating 26.4 V, ON voltage 18 V or higher, OFF current 0.2 mA or lower, ON current 2 mA (for 24 V)

          Inputs

          6 inputs (IN1 to IN6)

          Function

          IN1: External trigger, IN2 to IN6: Enable by assigning the optional functions
          Assignable functions: Programme switching, Clear error, External master image registration,
          Main unit/expansion unit simultaneous input

          Output

          Type

          Open collector output NPN/PNP is switchable, N.O./N.C. is switchable
          For open collector NPN output: Maximum rating 26.4 V 50 mA (20 mA when linked to an expansion unit [IV-HG15]), remaining voltage 1.5 V or lower
          For open collector PNP output: Maximum rating 26.4 V 50 mA (20 mA when linked to an expansion unit [IV-HG15]), remaining voltage 2 V or lower

          Outputs

          8 outputs (OUT1 to OUT8)

          Function

          Enable by assigning the optional functions
          Assignable functions: Total judgement result, RUN, BUSY, Error, Position adjustment result, Judgement result of each tool,
          Result of the logical operation of each tool, Main unit/expansion unit logical output

          Ethernet

          Standard

          100BASE-TX/10BASE-T*10

          Connector

          RJ-45 8pin connector*10

          Network function

          FTP client, EtherNet/IPTM, PROFINET

          Rating

          Power voltage

          24 VDC ±10 % (including ripple)

          Supplied from main unit

          Current consumption

          0.8 A or less. 1.5 A or less when also using an expansion unit (IV-HG15). (The output load is excluded.)

          Environmental resistance

          Ambient temperature

          0 to +50 °C (No freezing)*11

          Relative humidity

          35 to 85 % RH (No condensation)

          Material

          Main unit case: Polycarbonate

          Weight

          Approx. 150 g

          *1 Monochrome type only
          *2 Colour type only
          *3 Supported with Ver. R5.00.00 or later.
          *4 Tools can be installed by programmes.
          *5 When using the FTP client function: 70 pictures
          *6 When using the FTP client function: 210 pictures
          *7 Saves to the sensor amplifier's internal memory. The images saved to the sensor amplifier can be backed up to the USB memory device inserted into the intelligent monitor (IV-M30) or to the PC by the software for the IV-H/IV-HG Series (IV-H1).
          *8 This can be displayed on the intelligent monitor (IV-M30) or by software for the IV-H/IV-HG Series (IV-H1).
          *9 Possible with both the colour type and monochrome type
          *10 This is for connection with the intelligent monitor (IV-M30) or software for the IV-H/IV-HG Series (IV-H1).
          *11 When attaching the sensor amplifier to a DIN rail, attach the sensor amplifier to a metal plate.

          Sensor

          Model

          IV-H500CA

          IV-H500MA

          IV-H150MA

          IV-H2000MA

          Type

          Standard distance

          Short range

          Long range

          Installed distance

          50 to 500 mm

          50 to 150 mm

          300 to 2,000 mm

          View

          Installed distance 50 mm: 25 (H) x 18 (V) mm to
          installed distance 500 mm: 210 (H) x 157 (V) mm

          Installed distance 50 mm: 12 (H) x 9 (V) mm to
          installed distance 150 mm: 36 (H) x 27 (V) mm

          Installed distance 300 mm: 45 (H) x 33 (V) mm to
          installed distance 2,000 mm: 300 (H) x 225 (V) mm

          Image sensor

          Type

          1/3 inch colour CMOS

          1/3 inch monochrome CMOS

          Pixel

          752 (H) x 480 (V)

          Focus adjustment

          Auto*1

          Exposure time

          1/10 to 1/50,000

          1/10 to 1/25,000

          1/20 to 1/25,000

          1/10 to 1/25,000

          Lights

          Illumination

          White LED

          Red LED

          Infrared LED

          Lighting method

          Pulse lighting/DC lighting is switchable

          Tools

          Type

          Shape Detection, Colour Area*2, Area*3, Edge Pixels, Width/Height, Diameter, Edge Presence, Pitch, Position Adjustment, High Speed Position Adjustment (1-Axis/2-Axis Adjustment)

          Number

          Detection tools: 16 tools, position adjustment tool: 1 tool*4

          Switch settings (programs)

          32 programmes

          Image history

          Numbers

          100 images*5*6

          300 images*12*6

          Condition

          NG only/All is selectable*6

          Analysis information

          OFF/Statistics/Histograms/Matching rate list is switchable
          Statistics: Processing time (latest value, MAX, MIN, AVE), number of OKs, number of NGs, trigger numbers, trigger errors, judgement results list by tools
          Histograms: Histogram, matching degree (latest value, MAX, MIN, AVE), numbers of OKs, numbers of NGs
          Matching rate list: Judgment results list by tools, matching rate list by tools, judgment bar list by tools*7

          Other functions

          HDR, HighGain, Colour filters*2, Digital zoom*3, Brightness correction, Tilt correction, White balance*2,
          Mask function, Colour histogram, Test run, ToolAutoTune, Input monitor, Output test,
          Security settings, Simulator*8, Sensor date/time information addition, Scaling function, Failing sensor list, Failure hold

          Indicators

          PWR/ERR, OUT, TRIG, STATUS, LINK/ACT

          Input

          Type

          Non-voltage input/voltage input is switchable
          For non-voltage input: ON voltage 2 V or lower, OFF current 0.1 mA or lower, ON current 2 mA (short circuit)
          For voltage input: Maximum input rating 26.4 V, ON voltage 18 V or higher, OFF current 0.2 mA or lower, ON current 2 mA (for 24 V)

          Inputs

          6 inputs (IN1 to IN6)

          Function

          IN1: External trigger, IN2 to IN6: Enable by assigning the optional functions
          Assignable functions: Programme switching, Clear error, External master image registration

          Output

          Type

          Open collector output NPN/PNP is switchable, N.O./N.C. is switchable
          For open collector NPN output: Maximum rating 26.4 V 50 mA, remaining voltage 1.5 V or lower
          For open collector PNP output: Maximum rating 26.4 V 50 mA, remaining voltage 2 V or lower

          Outputs

          4 outputs (OUT1 to OUT4)

          Function

          Enable by assigning the optional functions
          Assignable functions: Total judgement result, RUN, BUSY, Error, Position adjustment result, Judgement result of each tool,
          Result of the logical operation of each tool, Main unit/expansion unit logical output

          Ethernet

          Standard

          100BASE-TX/10BASE-T*9

          Connector

          M12 4pin connector*9

          Network function

          FTP client, EtherNet/IPTM, PROFINET

          Rating

          Power voltage

          24 VDC ±10 % (including ripple)

          Current consumption

          0.6 A or less

          Environmental resistance

          Enclosure rating

          IP67*10

          Ambient temperature

          0 to +50 °C (No freezing)

          Relative humidity

          35 to 85 % RH (No condensation)

          Vibration resistance

          10 to 55 Hz, Double amplitude 1.5 mm, 2 hours in each of the X, Y, and Z directions*11

          10 to 55 Hz, Double amplitude 1.5 mm, 2 hours in each of the X, Y, and Z directions*13

          10 to 55 Hz, Double amplitude 1.5 mm, 2 hours in each of the X, Y, and Z directions*11

          Shock resistance

          500 m/s2, 3 times in each of 6 directions*11

          Material

          Main unit case: Aluminium die-casting, Packing: NBR, Front cover: Acrylic, Mounting adapter: POM

          Weight

          Approx. 270 g

          *1 The focusing position can be automatically adjusted at the time of installation. Deactivated during the operation. Focusing position can be registered by programme.
          *2 Colour type only
          *3 Possible with both the colour type and monochrome type
          *4 Tools can be installed by programmes.
          *5 When using the FTP client function: 70 pictures
          *6 Saves to the memory in the sensor. The images saved in the sensor can be backed up to the USB memory installed to the intelligent monitor (IV-M30) or to the PC by the software for IV (IV-H1).
          *7 This can be displayed on the intelligent monitor (IV-M30) or by software for IV (IV-H1).
          *8 Simulator can be used with the IV software (IV-H1).
          *9 This is for connection with the intelligent monitor (IV-M30) or software for IV (IV-H1).
          *10 Except when polarised filter attachment (OP-87436/OP-87437) is mounted
          *11 Except when IV-G dome attachment (IV-D10) is mounted
          *12 When using the FTP client function: 210 pictures
          *13 Except when IV-H dome attachment (IV-D10) is mounted

          Sensor Head

          Model

          IV-G500CA

          IV-G500MA

          IV-G150MA

          IV-G300CA

          IV-G600MA

          Type

          Standard sensor model

          Narrow field of view sensor model

          Wide field of view sensor model

          Installed distance

          20 to 500 mm

          40 to 150 mm

          40 to 300 mm

          40 to 600 mm

          View

          Installed distance 20 mm: 10 (H) x 7.5 (V) mm to
          Installed distance 500 mm: 200 (H) x 150 (V) mm

          Installed distance 40 mm: 8 (H) x 6 (V) mm to
          Installed distance 150 mm: 32 (H) x 24 (V) mm*4

          Installed distance 40 mm: 42 (H) x 31 (V) mm to
          installed distance 300 mm: 275 (H) x 206 (V) mm

          Installed distance 40 mm: 42 (H) x 31 (V) mm to
          installed distance 600 mm: 550 (H) x 412 (V) mm

          Image sensor

          Type

          1/3 inch colour CMOS

          1/3 inch monochrome CMOS

          1/3 inch colour CMOS

          1/3 inch monochrome CMOS

          Pixel

          752 (H) x 480 (V)

          Focus adjustment

          Auto*1

          Exposure time

          1/10 to 1/50,000

          1/20 to 1/50,000

          1/25 to 1/50,000

          1/50 to 1/50,000

          Lights

          Illumination

          White LED

          Infrared LED

          Lighting method

          Pulse lighting/DC lighting is switchable

          Pulse lighting

          Indicators

          2 (the same display details for both indicators)

          Environmental resistance

          Enclosure rating

          IP67*2

          Ambient temperature

          0 to +50 °C (No freezing)

          Relative humidity

          35 to 85 % RH (No condensation)

          Vibration resistance

          10 to 55 Hz, Double amplitude 1.5 mm, 2 hours in each of the X, Y, and Z directions*3

          Shock resistance

          500 m/s2, 3 times in each of 6 directions*3

          Material

          Main unit case: Zinc die-casting, Front cover: Acrylic (hard coat), Operation indicator cover: TPU

          Weight

          Approx. 75 g

          *1 The focusing position can be automatically adjusted at the time of installation. Deactivated during the operation. Focusing position can be registered by programme.
          *2 Except when polarised filter attachment (OP-87899/OP-87900/OP-87901/OP-87902) is mounted
          *3 Except when IV-G dome attachment (IV-GD05/IV-GD10) is mounted
          *4 Installed distance 18 mm: 4 (H) x 3 (V) mm to installed distance 27 mm: 7 (H) x 5.2 (V) mm when the magnifying lens attachment (OP-87902) is used

          Sensor Amplifier

          Model

          IV-G10

          IV-G15

          Type

          Main unit

          Expansion unit

          Tools

          Type

          Shape Detection, Area*1, Colour Area*2, position adjustment

          Number

          Detection tools: 16 tools, position adjustment tool: 1 tool*3

          Switch settings (programs)

          32 programmes

          Image history

          Numbers

          When using a colour type head: 100 images*4, when using a monochrome type head: 300 images*5*6

          Condition

          NG only/All is selectable*6

          Analysis information

          OFF/Statistics/Histograms is switchable
          Statistics: Processing time (latest value, MAX, MIN, AVE), number of OKs, number of NGs, trigger numbers, trigger errors, judgement results list by tools
          Histograms: Histogram, matching degree (latest value, MAX, MIN, AVE), numbers of OKs, numbers of NGs*7

          Other functions

          HDR, HighGain, Colour filters*2, Digital zoom (2x, 4x)*8, Brightness correction, Tilt correction, White balance*2, Mask outline, Mask area, Test run, ToolAutoTune, Input monitor,
          Output test, Security settings, Simulator, Mutual interference prevention, Total judgement result output, Direct connection (2 units or more), Failing sensor list, Failure hold

          Indicators

          PWR/ERR, OUT, TRIG, STATUS, LINK/ACT

          Input

          Type

          Non-voltage input/voltage input is switchable
          For non-voltage input: ON voltage 2 V or lower, OFF current 0.1 mA or lower, ON current 2 mA (short circuit)
          For voltage input: Maximum input rating 26.4 V, ON voltage 18 V or higher, OFF current 0.2 mA or lower, ON current 2 mA (for 24 V)

          Inputs

          6 inputs (IN1 to IN6)

          Function

          IN1: External trigger, IN2 to IN6: Enable by assigning the optional functions
          Assignable functions: Program switching, Clear error, External master image registration, Main unit/expansion unit simultaneous input

          Output

          Type

          Open collector output NPN/PNP is switchable, N.O./N.C. is switchable
          For open collector NPN output: Maximum rating 26.4 V 50 mA (20 mA when linked to an expansion unit [IV-G15]), remaining voltage 1.5 V or lower
          For open collector PNP output: Maximum rating 26.4 V 50 mA (20 mA when linked to an expansion unit [IV-G15]), remaining voltage 2 V or lower

          Outputs

          8 outputs (OUT1 to OUT8)

          Function

          Enable by assigning the optional functions
          Assignable functions: Total judgement result, RUN, BUSY, Error, Position adjustment result, Judgement result of each tool,
          Result of the logical operation of each tool, Main unit/expansion unit logical output

          Ethernet

          Standard

          100BASE-TX/10BASE-T*9

          Connector

          RJ-45 8pin connector*9

          Network function

          FTP client, EtherNet/IPTM, PROFINET

          Rating

          Power voltage

          24 VDC ±10 % (including ripple)

          Supplied from main unit

          Current consumption

          0.8 A or less. 1.5 A or less when also using an expansion unit (IV-G15). (The output load is excluded.)

          Environmental resistance

          Ambient temperature

          0 to +50 °C (No freezing)*10

          Relative humidity

          35 to 85 % RH (No condensation)

          Material

          Main unit case: Polycarbonate

          Weight

          Approx. 150 g

          *1 Monochrome type only
          *2 Colour type only
          *3 Tools can be installed by programmes.
          *4 When using the FTP client function: 70 pictures
          *5 When using the FTP client function: 210 pictures
          *6 Saves to the sensor amplifier's internal memory. The images saved to the sensor amplifier can be backed up to the USB memory device inserted into the intelligent monitor (IV-M30) or to the PC by the software for the IV/IV-G Series (IV-H1).
          *7 This can be displayed on the intelligent monitor (IV-M30) or by software for the IV/IV-G Series (IV-H1).
          *8 Possible with both the colour type and monochrome type
          *9 This is for connection with the intelligent monitor (IV-M30) or software for the IV/IV-G Series (IV-H1).
          *10 When attaching the sensor amplifier to a DIN rail, attach the sensor amplifier to a metal plate.

          Sensor

          Model

          IV-500CA

          IV-500C

          IV-500MA

          IV-500M

          IV-150MA

          IV-150M

          IV-2000MA

          IV-2000M

          Type

          Standard distance

          Short range

          Long range

          Installed distance

          50 to 500 mm

          50 to 150 mm

          300 to 2,000 mm

          View

          Installed distance 50 mm: 25 (H) x 18 (V) mm to
          installed distance 500 mm: 210 (H) x 157 (V) mm

          Installed distance 50 mm: 12 (H) x 9 (V) mm to
          installed distance 150 mm: 36 (H) x 27 (V) mm

          Installed distance 300 mm: 45 (H) x 33 (V) mm to
          installed distance 2,000 mm: 300 (H) x 225 (V) mm

          Image sensor

          Type

          1/3 inch colour CMOS

          1/3 inch monochrome CMOS

          Pixel

          752 (H) x 480 (V)

          Focus adjustment

          Auto*1

          Manual

          Auto*1

          Manual

          Auto*1

          Manual

          Auto*1

          Manual

          Exposure time

          1/10 to 1/50,000

          1/10 to 1/25,000

          1/20 to 1/25,000

          1/10 to 1/25,000

          Lights

          Illumination

          White LED

          Red LED

          Infrared LED

          Lighting method

          Pulse lighting/DC lighting is switchable

          Tools

          Type

          Shape Detection, Colour Area*2, Area*3, position adjustment

          Number

          Detection tools: 16 tools, position adjustment tool: 1 tool*4

          Switch settings (programs)

          32 programmes

          Image history

          Numbers

          100 images*5*6

          300 images*12*6

          Condition

          NG only/All is selectable*6

          Analysis information

          OFF/Statistics/Histograms is switchable
          Statistics: Processing time (latest value, MAX, MIN, AVE), number of OKs, number of NGs, trigger numbers, trigger errors, judgement results list by tools
          Histograms: Histogram, matching degree (latest value, MAX, MIN, AVE), numbers of OKs, numbers of NGs
          *7

          Other functions

          HDR, HighGain, Colour filters*2, Digital zoom*3, Brightness correction, Tilt correction, White balance*2,
          Mask outline, Mask area, Test run, ToolAutoTune, Input monitor, Output test,
          Security settings, Simulator*8

          Indicators

          PWR/ERR, OUT, TRIG, STATUS, LINK/ACT

          Input

          Type

          Non-voltage input/voltage input is switchable
          For non-voltage input: ON voltage 2 V or lower, OFF current 0.1 mA or lower, ON current 2 mA (short circuit)
          For voltage input: Maximum input rating 26.4 V, ON voltage 18 V or higher, OFF current 0.2 mA or lower, ON current 2 mA (for 24 V)

          Inputs

          6 inputs (IN1 to IN6)

          Function

          IN1: External trigger, IN2 to IN6: Enable by assigning the optional functions
          Assignable functions: Program switching, Clear error, External master image registration

          Output

          Type

          Open collector output NPN/PNP is switchable, N.O./N.C. is switchable
          For open collector NPN output: Maximum rating 26.4 V 50 mA, remaining voltage 1.5 V or lower
          For open collector PNP output: Maximum rating 26.4 V 50 mA, remaining voltage 2 V or lower

          Outputs

          4 outputs (OUT1 to OUT4)

          Function

          Enable by assigning the optional functions
          Assignable functions: Total judgement result, RUN, BUSY, Error, Position adjustment result, Judgement result of each tool,
          Result of the logical operation of each tool, Main unit/expansion unit logical output

          Ethernet

          Standard

          100BASE-TX/10BASE-T*9

          Connector

          M12 4pin connector*9

          Network function

          FTP client, EtherNet/IPTM, PROFINET

          Rating

          Power voltage

          24 VDC ±10 % (including ripple)

          Current consumption

          0.6 A or less

          Environmental resistance

          Enclosure rating

          IP67*10

          Ambient temperature

          0 to +50 °C (No freezing)

          Relative humidity

          35 to 85 % RH (No condensation)

          Vibration resistance

          10 to 55 Hz, Double amplitude 1.5 mm, 2 hours in each of the X, Y, and Z directions*11

          Shock resistance

          500 m/s2, 3 times in each of 6 directions*11

          Material

          Main unit case: Aluminium die-casting, Packing: NBR, Front cover: Acrylic, Mounting adapter: POM

          Weight

          Approx. 270 g

          *1 The focusing position can be automatically adjusted at the time of installation. Deactivated during the operation. Focusing position can be registered by programme.
          *2 Colour type only
          *3 Possible with both the colour type and monochrome type
          *4 Tools can be installed by programmes.
          *5 When using the FTP client function: 70 pictures
          *6 Saves to the memory in the sensor. The images saved in the sensor can be backed up to the USB memory installed to the intelligent monitor (IV-M30) or to the PC by the software for IV (IV-H1).
          *7 This can be displayed on the intelligent monitor (IV-M30) or by software for IV (IV-H1).
          *8 Simulator can be used with the IV software (IV-H1).
          *9 This is for connection with the intelligent monitor (IV-M30) or software for IV (IV-H1).
          *10 Except when polarised filter attachment (OP-87436/OP-87437) is mounted
          *11 Except when IV-G dome attachment (IV-D10) is mounted
          *12 When using the FTP client function: 210 pictures

          MONITOR

          Model

          IV-M30

          Supported languages

          Japanese/English/German/Simplified Chinese/Traditional Chinese

          Display

          3.5" TFT colour LCD 320 x 240 dot (QVGA)

          Backlight

          Method

          White LED

          Duration

          Approx 50,000 hours (25 °C)

          Touch panel

          Method

          Analogue resistive

          Actuating force

          0.8 N or less

          Expanded memory

          USB memory*1

          Indicators

          PWR, SENSOR

          Ethernet

          Standard

          100BASE-TX/10BASE-T*2

          Connector

          M12 4pin connector*2

          Rating

          Power voltage

          24 VDC ±10 % (including ripple)

          Current consumption

          0.2 A or less

          Environmental resistance

          Ambient temperature

          0 to +50 °C (No freezing)

          Relative humidity

          35 to 80 % RH (No condensation)*3

          Drop resistance

          1.3 m over the concrete (2 times each in the arbitrary direction)

          Vibration resistance

          10 to 55 Hz, Double amplitude 0.7 mm, 20 sweeps in each of the X, Y, and Z directions

          Material

          Polycarbonate

          Weight

          Approx. 180 g

          *1 Use the KEYENCE recommended product.
          *2 This is dedicated for connection with IV-series sensor.
          *3 If the ambient temperature is over 40 °C, use it in the absolute humidity of 40 °C 80 % RH or lower.

          SOFTWARE

          Model

          IV-H1

          Type

          Software for the IV-H Series

          Operating System

          Windows 10 Home/Pro/Enterprise*1
          Windows 7 Home Premium/Professional/Ultimate*1
          Windows XP Professional/Home Edition; either of OS above needs to be pre-installed

          Supported languages

          Japanese/English/German/Simplified Chinese/Traditional Chinese/
          Italian/French/Spanish/Portuguese/Korean

          CPU

          Windows 10/7: needs to be compliant with system requirements for OS
          Windows XP: Pentium III or better, Clock speed 1 GHz or faster

          Memory capacity

          Windows 10/7: needs to be compliant with system requirements for OS
          Windows XP: 512 MB or more (1 GB or more is recommended)

          Available hard disk space

          1 GB or more

          Display

          Resolution 1,024 x 768 pixels or higher, Display colour High Colour (16 bit) or higher

          PC interface

          Equip the Ethernet (100BASE-TX) interface

          Note

          .NET Framework 4.0 or 4.5 needs to be installed*2

          *1 Supported for 32 bit and 64 bit version.
          *2 If .NET Framework 4.0 or 4.5 is not installed, this will be automatically installed at the time of IV-H1 installation.

          • VisionSystem.com
          • General Catalogue Request
          • Trade Shows and Exhibitions
          • eNews Subscribe

          More Series In Vision Sensors

          Types In Vision / Auto ID

          Vision / Auto ID