This model has been discontinued.
Compliance with the certification standard is ensured as of the time of shipment from our company.

Recommended Replaceable Products: Sensor Amplifier for IV-HG, Main unit - IV-HG10

For IV-G, Sensor Amplifier, Main unit IV-G10

IV-G10 - For IV-G, Sensor Amplifier, Main unit

*Please note that accessories depicted in the image are for illustrative purposes only and may not be included with the product.

Software

  • CE Marking
  • UL Recognition(c/us)

Specifications

Model

IV-G10

Type

Main unit

Tools

Type

Shape Detection, Area*1, Colour Area*2, position adjustment

Number

Detection tools: 16 tools, position adjustment tool: 1 tool*3

Switch settings (programs)

32 programmes

Image history

Numbers

When using a colour type head: 100 images*4, when using a monochrome type head: 300 images*5*6

Condition

NG only/All is selectable*6

Analysis information

OFF/Statistics/Histograms is switchable
Statistics: Processing time (latest value, MAX, MIN, AVE), number of OKs, number of NGs, trigger numbers, trigger errors, judgement results list by tools
Histograms: Histogram, matching degree (latest value, MAX, MIN, AVE), numbers of OKs, numbers of NGs*7

Other functions

HDR, HighGain, Colour filters*2, Digital zoom (2x, 4x)*8, Brightness correction, Tilt correction, White balance*2, Mask outline, Mask area, Test run, ToolAutoTune, Input monitor,
Output test, Security settings, Simulator, Mutual interference prevention, Total judgement result output, Direct connection (2 units or more), Failing sensor list, Failure hold

Indicators

PWR/ERR, OUT, TRIG, STATUS, LINK/ACT

Input

Type

Non-voltage input/voltage input is switchable
For non-voltage input: ON voltage 2 V or lower, OFF current 0.1 mA or lower, ON current 2 mA (short circuit)
For voltage input: Maximum input rating 26.4 V, ON voltage 18 V or higher, OFF current 0.2 mA or lower, ON current 2 mA (for 24 V)

Inputs

6 inputs (IN1 to IN6)

Function

IN1: External trigger, IN2 to IN6: Enable by assigning the optional functions
Assignable functions: Program switching, Clear error, External master image registration, Main unit/expansion unit simultaneous input

Output

Type

Open collector output NPN/PNP is switchable, N.O./N.C. is switchable
For open collector NPN output: Maximum rating 26.4 V 50 mA (20 mA when linked to an expansion unit [IV-G15]), remaining voltage 1.5 V or lower
For open collector PNP output: Maximum rating 26.4 V 50 mA (20 mA when linked to an expansion unit [IV-G15]), remaining voltage 2 V or lower

Outputs

8 outputs (OUT1 to OUT8)

Function

Enable by assigning the optional functions
Assignable functions: Total judgement result, RUN, BUSY, Error, Position adjustment result, Judgement result of each tool,
Result of the logical operation of each tool, Main unit/expansion unit logical output

Ethernet

Standard

100BASE-TX/10BASE-T*9

Connector

RJ-45 8pin connector*9

Network function

FTP client, EtherNet/IP®, PROFINET

Rating

Power voltage

24 VDC ±10 % (including ripple)

Current consumption

0.8 A or less. 1.5 A or less when also using an expansion unit (IV-G15). (The output load is excluded.)

Environmental resistance

Ambient temperature

0 to +50 °C (No freezing)*10

Relative humidity

35 to 85 % RH (No condensation)

Material

Main unit case: Polycarbonate

Weight

Approx. 150 g

*1 Monochrome type only
*2 Colour type only
*3 Tools can be installed by programmes.
*4 When using the FTP client function: 70 pictures
*5 When using the FTP client function: 210 pictures
*6 Saves to the sensor amplifier's internal memory. The images saved to the sensor amplifier can be backed up to the USB memory device inserted into the intelligent monitor (IV-M30) or to the PC by the software for the IV/IV-G Series (IV-H1).
*7 This can be displayed on the intelligent monitor (IV-M30) or by software for the IV/IV-G Series (IV-H1).
*8 Possible with both the colour type and monochrome type
*9 This is for connection with the intelligent monitor (IV-M30) or software for the IV/IV-G Series (IV-H1).
*10 When attaching the sensor amplifier to a DIN rail, attach the sensor amplifier to a metal plate.

Data Sheet (PDF) Other Models