          SPECIFICATIONS

          Select Language

          Model

          SZ-V32X*1

          Type

          Multi-bank Type

          Detection
          capability

          Minimum detectable object size

          Diameter: 20, 30, 40, 50, 70, 150 mm (depends on the setting);
          Reflectance: 1.8% min.; Speed: 1.6 m/s max.*2

          Detectable angle

          190° (-5° to 185°)

          Response time
          (ON to OFF)

          Standard Mode

          Scan Cycle A

          160 ms (2 scans) to 1280 ms (16 scans)*3

          Scan Cycle B

          168 ms (2 scans) to 1344 ms (16 scans)*3

          Scan Cycle C

          176 ms (2 scans) to 1408 ms (16 scans)*3

          High Speed Mode

          Scan Cycle A

          80 ms (2 scans) to 640 ms (16 scans)*3

          Scan Cycle B

          84 ms (2 scans) to 672 ms (16 scans)*3

          Scan Cycle C

          88 ms (2 scans) to 704 ms (16 scans)*3

          Response time (OFF to ON)

          Response time of ON to OFF + 150 ms

          Protection
          zone

          Minimum detectable object size: 70 / 150 mm

          Standard Mode: 8.4 m / High Speed Mode: 5.7 m

          Minimum detectable object size: 50 mm

          Standard Mode: 5.6 m / High Speed Mode: 3.8 m

          Minimum detectable object size: 40 mm

          Standard Mode: 4.3 m / High Speed Mode: 2.9 m

          Minimum detectable object size: 30 mm

          Standard Mode: 2.9 m / High Speed Mode: 2.0 m

          Minimum detectable object size: 20 mm

          Standard Mode: 1.6 m / High Speed Mode: 1.1 m

          Warning
          zone

          Minimum detectable object size: 70 / 150 mm

          Standard Mode: 26 m / High Speed Mode: 23 m*4

          Minimum detectable object size: 50 mm

          Standard Mode: 25 m / High Speed Mode: 21 m*4

          Minimum detectable object size: 40 mm

          Standard Mode: 24 m / High Speed Mode: 20 m*4

          Minimum detectable object size: 30 mm

          Standard Mode: 23 m / High Speed Mode: 18 m*4

          Minimum detectable object size: 20 mm

          Standard Mode: 21 m / High Speed Mode: 15 m*4

          Additional safety distance

          100 mm*5

          Maximum measurement distance

          60 m*6

          Maximum number of banks

          Max. 32 banks

          Multiple scanner heads

          Max. 3

          Camera

          Monitor area: over 190° (-5° to 185°)*7

          Display

          QVGA 2.2 inch colour LCD

          Light source

          Type, wavelength

          Infrared laser diode, 905 nm

          Laser class

          IEC

          Class 1 IEC / EN 60825-1

          FDA

          Class 1 FDA 21 CFR 1040.10, 1040.11 (Laser Notice No.50)*8

          JIS

          Class 1 JIS C6802

          Control output
          (OSSD output)

          Output type

          PNP or NPN transistor output (settings configurable with SZ-V Configurator)

          Number of outputs

          2 outputs

          Max. load current

          500 mA*9

          Residual voltage

          Max. 2.5 V (with a cable length of 5 m)

          OFF-state voltage

          Max. 2.0 V (with a cable length of 5 m)

          Leakage current

          Max. 1 mA*10

          Max. capacitive load

          2.2 µF (with a load resistance of 100 Ω)

          Load wiring resistance

          Max. 2.5 Ω

          Input
          (safety-related)

          PNP

          ON-voltage: 10 to 30 V,
          OFF-voltage: Open or 0 to 3 V,
          Short-circuit current: Approx. 2.5 mA (EDM input: Approx. 10 mA)

          NPN

          ON-voltage: 0 to 3 V,
          OFF-voltage: Open or 10 V to Power voltage,
          Short-circuit current: Approx. 2.5 mA (Approx. 10 mA for EDM)

          Non
          safety-related
          output
          (AUX output)

          Output type

          Transistor output (PNP or NPN, settings configurable with SZ-V Configurator)

          Number of outputs

          4 outputs

          Max. load current

          50 mA

          Residual voltage (during ON)

          Max. 2.5 V (with a cable length of 5 m)

          Muting lamp

          -

          Interface

          USB

          USB 2.0

          Ethernet

          Standard

          -

          Transmission rate

          Cable

          Connector

          Networking/data output

          Cable length

          Power cable

          30 m or less*11

          Connection cable

          20 m or less each*12

          Ethernet cable

          -

          Approved
          standards

          EMC

          EMS

          IEC61496-1, EN61496-1, UL61496-1 (Type3 ESPE)

          EMI

          EN55011 Class A, FCC Part15B Class A, ICES-003 Class A

          Safety

          IEC61496-1, EN61496-1, UL61496-1 (Type3 ESPE),
          IEC61496-3, EN61496-3 (Type3 AOPDDR),
          IEC61508, EN61508, IEC62061, EN62061 (SIL2/SILCL2),
          EN ISO13849-1:2015 (PLd, Category3), IEC61784-3-3,
          UL508, UL1998, CSA C22.2 No.14, CSA C22.2 No.0.8

          Rating

          Power consumption

          11.8 W (without load), 55.0 W (with load)*13

          Power voltage

          When using a converter power supply: 24 VDC ±10 %, Ripple (P-P) 10 % or less
          When using a battery: 24 VDC +20 % /-30 %

          Environmental resistance

          Enclosure rating

          IP65 (IEC60529)

          Ambient light

          Incandescent lamp: 1,500 lux or less*14

          Operating ambient temperature

          -10 to +50 °C (No freezing)

          Storage temperature

          -25 to +60 °C (No freezing)

          Operating relative humidity

          35 to 85 % RH (No condensation)

          Storage relative humidity

          35 to 95 % RH

          Vibration resistance

          10 to 55 Hz, Double amplitude 0.7 mm, 20 sweeps in each of the X, Y, and Z directions

          Shock resistance

          100 m/s2 (Approx. 10 G), 16 ms pulse, 1,000 times in each of the X, Y, and Z directions

          Material

          Scanner head

          Main unit case

          Magnesium

          Window

          Polycarbonate, PEI

          Indicator part

          Aluminum, PES*7

          Display unit

          case

          Magnesium, PPS, Polycarbonate

          System memory

          Aluminum, PPE

          Weight

          Approx. 2,100 g

          *1 Integrated models include display unit, scanner head, system memory and a connection cable (SZ-VS005).
          *2 If the object to be detected moves perpendicular to the detection plane, SZ-V cannot detect the object moving at speed over 1.6 m/s, regardless of the encoder setting.
          *3 The response time, protection zone, and warning zone are affected by the operation mode.
          *4 20% or more reflectance is necessary for the minimum detectable object in the warning zone.
          *5 If there is a highly reflective background within 1.5 m from the boundary of the protection zone, 200 mm must be added as supplementary necessary distance to the protection zone when calculating the minimum safety distance.
          *6 Even when using the network data output, the maximum measured output distance is 60 m.
          *7 Only applicable for the type with a camera.
          *8 The laser classification for FDA (CDRH) is implemented based on IEC60825-1 in accordance with the requirements of Laser Notice No.50.
          *9 The load current calculation of the OSSD output and AUX output is 1.5 A or less when using one scanner head, 1.0 A or less when using two scanner heads, and 0.5 A or less when using three scanner heads.
          *10 Includes when the power is OFF.
          *11 10 m or less when supplying power from a battery.
          *12 When supplying power from a battery, the length of each connection cable should be 10 m or less when using two scanner heads, and 5 m or less when using three scanner heads.
          *13 When using the SZ-V with series connected sensor heads, it is necessary to add 9.4 W per scanner head. Also, power consumption may temporarily be higher (maximum 3.6 W). Power consumption will be within the specification after SZ-V moves to normal operation.
          *14 An ambient light source should not be located within ±5° of the detection plane.