          Non-Wetted Electrode Electromagnetic Flow SensorsFD-M series

          FD-MA1A

          Amplifier Unit, DIN Rail Mount Type, Main Unit, NPN

          SPECIFICATIONS

          Select Language

          Model

          FD-MA1A*1

          Type

          DIN mounted*2 (Main unit)

          Rated flow range

          FD-MH10A : 0.5 to 10L/min, FD-MH50A : 2.5 to 50L/min, FD-MH100A : 5 to 100L/min, FD-MH500A : 25 to 500L/minThe rated flow range indicates the range that is supposed to be used in general.*3

          Possible display range

          FD-MH10A : 0.5 to 20L/min, FD-MH50A : 2.5 to 100L/min, FD-MH100A : 5 to 200L/min, FD-MH500A : 25 to 1000L/min*4

          Possible ranges to set

          FD-MH10A : 0 to 20 L/min,FD-MH50A : 0 to 100 L/min,FD-MH100A : 0 to 200 L/min,FD-MH500A : 0-999.9 L/min

          Zero-cut flow rate

          FD-MH10A : 0.5L/min, FD-MH50A : 2.5L/min, FD-MH100A : 5L/min, FD-MH500A : 25L/min*4

          Display power

          Dual row display with 4-digit, 7 segment LED, other indicators

          Display resolution

          FD-MH10A: 0.01/0.1 (L/min) selectable, FD-MH50A: 0.1/1 (L/min) selectable, FD-MH100A: 0.1/1 (L/min) selectable, FD-MH500A: 0.1/1 (L/min) selectable

          Repeatability

          0.5 s : ±5% of F.S.,1 s : ±3.5% of F.S., 2.5 s : ±2.5% of F.S., 5 s : ±1.6% of F.S., 10 s : ±1% of F.S., 30 s : ±0.8% of F.S., 60 s : ±0.6% of F.S.*5

          Hysteresis

          Variable

          Response time (chatter prevention feature)

          500 ms/1 s/2.5 s/5 s/10 s/30 s/60 s variable

          Accumulated flow unit

          FD-MH10A : 0.01/0.1/1/10/100 (ℓ) selectable,FD-MH50A : 0.1/1/10/100/1000 (ℓ) selectable,FD-MH100A : 0.1/1/10/100/1000 (ℓ) selectable,FD-MH500A : 1/10/100/1000/10000 (ℓ) selectable

          Accumulation data storage cycle

          Save to memory every 10 seconds

          Memory backup

          EEPROM (Data storage length : min. 10 years, Data read/write frequency : min. 1 million times)

          Control output

          Maximum NPN open-collector output : 100 mA/ch*6 (40 V or less)

          Analogue output

          4-20 mA, max. load resistance 260Ω, Analogue output range can be set to any value

          Integration reset/bank switch input/flow zero function input

          |input time : 20 ms or greater, Either accumulation reset or bank switching mode can be selected

          Power/current consumption

          Normal : 1700 mW (70 mA), Power save : 1440 mW (60 mA)

          Rating

          Power voltage

          24 VDC, Ripple (P-P) 10 % or less

          Environmental resistance

          Ambient temperature

          0 to +50 °C (No freezing)

          Relative humidity

          35 to 85 % RH (No condensation)

          Vibration resistance

          10 to 55 Hz, Double amplitude 1.5 mm, 2 hours in each of the X, Y, and Z directions

          Material

          Main case : polycarbonate, Key tops : polyacetal, Front sheet : polycarbonate, Cable : PVC

          Accessories

          instruction manual

          Weight

          Approx. 115 g

          *1 The models with “A” at the end of the name have additional functions such as display averaging. Use the head with “A” at the end of the name. When connecting conventional heads without “A” at the end, the FD-MH operates in the same way
          as the conventional models.
          *2 Only connect to the back of DL-RS1 (A) or FD-MA.
          *3 The rated flow range indicates recommended operating range.
          *4 Flow under the zero cut flow will be displayed as 0 L/min.
          *5 Convert the F.S. (full scale) listed in the table according to the rated flow range.
          *6 Maximum 20 mA for alarm output. When the total number of extension units is between 6 and 10, set each output current to 10 mA or less.