          Non-Wetted Electrode Electromagnetic Flow SensorsFD-M series

          FD-M100ATP

          Main Unit, Portrait, 100 L/min, PNP

          SPECIFICATIONS

          Select Language

          Model

          FD-M100ATP*1

          Type

          For vertical piping

          Shape

          Built-in amplifier

          Rated flow range

          5 to 100 L/min*2*3

          Possible display range

          5 to 200 L/min*4

          Possible ranges to set

          0 to 200 L/min

          Zero-cut flow rate

          5 L/min*5

          Connection diameter

          Rc1 (25A)

          Allowable fluid

          Water or non-corrosive liquid

          Conductivity of detection fluids

          5 µS/cm or higher

          Detection fluid temperature

          0 to +85°C (No freezing)

          Pressure loss

          0.01 MPa or less

          Display power

          Dual row display with 4-digit, 7 segment LED, bar display (2 colours), output indicators, flow indicator

          Display resolution

          0.1/1 (L/min) selectable

          Repeatability

          0.5 s : ±5% of F.S.
          10 s : ±1% of F.S.
          1 s : ±3.5% of F.S.
          30 s : ±0.8% of F.S.
          2.5 s : ±2.5% of F.S.
          60 s : ±0.6% of F.S.
          5 s : ±1.6% of F.S.*6

          Hysteresis

          Variable

          Response time (chatter prevention feature)

          500 ms/1 s/2.5 s/5 s/10 s/30 s/60 s variable

          Accumulated flow unit

          0.1/1/10/100/1000 (L) selectable

          Accumulation data storage cycle

          Save to memory every 10 seconds

          Memory backup

          EEPROM (Data storage length : 10 years or longer, Data read/write frequency : 1 million times or more)

          Control output

          PNP open collector, max. 100 mA/ch*7 (30 V or less), residual voltage 1 V or less, 3 outputs (N.O./N.C. switchable)

          Analogue output

          4-20 mA, max. load resistance 260Ω, Analogue output range can be set to any value

          Integration reset/bank switch input/flow zero function input

          Input time : 20 ms or greater, Either accumulation reset or bank switching mode can be selected

          Power/current consumption

          Normal : 1700 mW (70 mA), Power save : 1000 mW (40 mA)

          Rating

          Power voltage

          24 VDC, Ripple (P-P) 10 % or less

          Environmental resistance

          Enclosure rating

          IP65

          Pressure resistance

          2.0 MPa

          Applied pressure range

          1.0 MPa or less

          Ambient temperature

          0 to +50 °C (No freezing)

          Relative humidity

          35 to 85 % RH (No condensation)

          Vibration resistance

          10 to 55 Hz, Double amplitude 1.5 mm, 2 hours in each of the X, Y, and Z directions

          Material

          Liquid end materials

          Bore : SCS13, Measurement pipe : PPS, O ring : fluoro-rubber (FKM)

          Material properties

          Other parts

          Plastic case areas : PPS, Metal case areas : SUS430, Cable : PVC

          Accessories

          Instruction manual

          Weight

          Approx. 1,310 g

          *1 The models with “A” at the end of the name have additional functions such as display averaging.
          *2 The rated flow range indicates the range that is supposed to be used in general.
          *3 The rated flow range indicates recommended operating range.
          *4 Can be used within the display range as well as within the rated flow range.
          *5 Flow under the zero cut flow will be displayed as 0 L/min.
          *6 The repeatability is effective within the display range. Convert the F.S. (full scale) listed in the table according to the rated flow range.
          *7 Maximum 20 mA for alarm output.