High-Accuracy Digital Contact Sensor

GT2 series

Catalogues View Catalogue

Amplifier Unit, Connector Type, NPN GT2-71CN

GT2-71CN - Amplifier Unit, Connector Type, NPN

*Please note that accessories depicted in the image are for illustrative purposes only and may not be included with the product.

Software

  • CE Marking
  • UL Recognition(c/us)

Specifications

Model

GT2-71CN

Mounting type

DIN-rail mount*1

Output

NPN output

Main unit/Expansion unit

Main unit

Power supply voltage

10 to 30 VDC, including 10 % ripple (P-P), Class 2

Power consumption

Normal

2,200 mW or less (73.3 mA or less at 30 V)

Power saving (Eco)

Eco half: 1,800 mW or less (60.0 mA or less at 30 V), Eco all: 1,700 mW or less (56.7 mA or less at 30 V)

Display range

-199.999.9 to 199.999.9

Display resolution

0.1 μm

Control input

Timing/preset/
reset/bank input

No-voltage input

Control output

HH/HI/GO/LO/LL

NPN open collector, 40 V 50 mA or less, residual voltage 1 V or less*2*3

Analogue output

-

Response time

hsp(3)/5/10/100/500/1,000 ms
(When using GT2-Pxxx, hsp(12)/20/40/400/2,000/4,000 ms)

Environmental resistance

Ambient temperature

-10 to +50 °C (GT2-71MCN/71MCP: -10 to +45 °C when expansion unit (s) is connected)

Relative humidity

35 to 85 % RH (No condensation)

Vibration resistance

10 to 55 Hz, Double amplitude 1.5 mm, 2 hours in each of the X, Y, and Z directions

Material

Main body case/front cover: polycarbonate (PC), Key top: polyacetal (POM),
Front sheet: polyethylene terephthalate (PET), Cable: polyvinyl chloride (PVC)

Weight

Approx. 70 g (not including the GT2-CA2M/CA5M/CA10M)

*1 When using the DIN-rail mount type, always mount it to a DIN-rail (mounted to a metal plate), and when adding expansion units, always use the end unit (OP-26751).
*2 When adding expansion units, there are the following restrictions according to the number of connected units.
[When 2 to 8 units are connected including the main unit]
Power supply voltage: 20 to 30 VDC, Control output current: 20 mA or less, (GT2-71MCN(P) only) Ambient temperature: -10 to 45 °C
[When 9 to 15 units are connected including the main unit]
Power supply voltage: 20 to 30 VDC, Control output current: 10 mA or less (including the DL-RB1A output current), Residual voltage: 1.5 V or lower, (GT2-71MCN(P) only) Ambient temperature: -10 to 45 °C
*3 The GT2-71MCN(P) does not have HH/LL.

Data Sheet (PDF) Other Models